{"product_id":"square-d-4-amp-overload-relay-lr3d08","title":"LR3D08 - Square D - Overload Relay","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003ch3\u003eProduct Specifications - LR3D08 - Square D Overload Relay\r\u003c\/h3\u003e\n\u003cdiv class=\"divTable\"\u003e\n\u003cdiv class=\"divTableBody\"\u003e\n\u003cdiv class=\"divTableRow\"\u003e\n\u003cdiv class=\"divTableCell\"\u003e\n\u003cul class=\"tds-list\"\u003e\n\u003cli\u003e\n\u003ch4 class=\"list-header\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"list-item\"\u003eLR3D08\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4 class=\"list-header\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"list-item\"\u003e\n\u003ca title=\"Schneider Electric\" href=\"\/collections\/schneider-electric\"\u003eSchneider Electric\u003c\/a\u003e \/ \u003ca href=\"\/collections\/square-d-breakers\" title=\"Square D\"\u003eSquare D\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4 class=\"list-header\"\u003e\u003cstrong\u003eFamily:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"list-item\"\u003eTeSys D\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4 class=\"list-header\"\u003e\u003cstrong\u003eAmp:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"list-item\"\u003e4\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"divTableCell\"\u003e\n\u003cul class=\"tds-list\"\u003e\n\u003cli\u003e\n\u003ch4 class=\"list-header\"\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"list-item\"\u003e\u003ca title=\"Overload Relays\" href=\"\/collections\/overload-relays\"\u003eOverload Relays\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4 class=\"list-header\"\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"list-item\"\u003eLR3D\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv class=\"divTable\"\u003e\n\u003cdiv class=\"divTableBody\"\u003e\n\u003cdiv class=\"divTableRow\"\u003e\n\u003cdiv class=\"divTableCell\"\u003e\n\u003cul class=\"tds-list\"\u003e\n\u003cli\u003e\n\u003ch4 class=\"list-header\"\u003e\u003cstrong\u003eDimensions (HxWxD):\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"list-item\"\u003e2.60 x 1.77 x 2.76\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4 class=\"list-header\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"list-item\"\u003e0.27 lbs\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cdiv class=\"divTable\"\u003e\n\u003cdiv class=\"divTableBody\"\u003e\n\u003cdiv class=\"divTableRow\"\u003e\n\u003cdiv class=\"divTableCell\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0074\/7149\/7286\/files\/UL.jpg?v=1674585871\" width=\"60px\" height=\"60px\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"divTableCell\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0074\/7149\/7286\/files\/CSA.jpg?v=1674585871\" alt=\"CSA Approved logo\" width=\"60px\" height=\"60px\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch3\u003eProduct Description - LR3D08 - Square D Overload Relay\r\u003c\/h3\u003e\n\u003cp\u003eLR3D08 is a TeSys LRD thermal overload relay from Schneider Electric to be used with a TeSys D contactor. It protects motors 1.1-1.5kW@400V thanks to a thermal range 2.5-4A , a tripping class 10A, for use with unbalanced loads. LR3D08 is a TeSys LRD thermal overload relay from Schneider Electric for direct mounting on TeSys D contactors. With a thermal setting range 2.5-4A and tripping class 10A, it protects unbalanced loads and motors 1.1-1.5kW@400V. It provides manual test \u0026amp; reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs\/Reach). Thermal overload protection relay, bimetallic type, for use with unbalanced loads (non differential). Direct mounting on the bottom terminals of a Tesys contactor LC1D09-D38 to form a compact starter. Light and compact, 45mm wide. Temperature compensated for a good accuracy of the protection. Manual control with test \u0026amp; reset buttons, manual \/ automatic reset selector. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. Can be completed with terminal blocks for separate mounting (LAD7B, LAD96) and remote control devices (LAD703, LA7D03).\u003c\/p\u003e\n\u003chr\u003e\n","brand":"Square D","offers":[{"title":"New","offer_id":41211639660653,"sku":"LR3D08","price":95.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0074\/7149\/7286\/files\/LR3D08-New-1_50e0a7fb-c90b-4974-b000-c05eb79cfdd3.jpg?v=1711650219","url":"https:\/\/www.canadabreakers.ca\/products\/square-d-4-amp-overload-relay-lr3d08","provider":"Canada Breakers","version":"1.0","type":"link"}